STD-TE 60 HIGH PRESSURE HYDROGEN RECIPROCATING TRIBOMETER - Qinsun
Produttore di strumenti di prova professionali
Hotline nazionale di consultazione:+86 021-64208466
Prodotti

STD-TE 60 HIGH PRESSURE HYDROGEN RECIPROCATING TRIBOMETER

DescriptionSTD-TE 60 is a three-station reciprocating tribometer, designed around a high pressure c

WhatsApp : +86 13816217984

Email : info@qinsun-lab.com

Contenuto

Descrizione

STD-TE 60 is a three-station reciprocating tribometer, designed around a high pressure chamber, for experiments under hydrogen and other gases. It includes a vacuum pump for purging the chamber before charging with a chosen gas, so can also be used for tests under medium vacuum. Tests may be run with plate specimen temperatures from -50°C to +150°C.

Specifiche tecniche

Specifiche tecniche


Number of Test Stations:Three
Test Configuration:Ball on Flat

Cylinder on Flat
Gases:Hydrogen, Argon, CO2
Working Pressure:0.1 mbar to 100 bar
Proof Pressure:120 bar
Stroke Range:0 to 20 mm Continuously Adjustable
Frequency:0 to 5 Hz
Motion:Sinusoidal
Loading System:Tension Spring
Load Range:5 to 100 N
Friction Range:0 to 50 N
Deflection Sensor:Inductive Transducer
Pressure Rating:150 bar
Refrigerant Probe:
Action:Contact cooling of plate specimen
Temperature Range:Ambient to -50°C
Heating Probe:
Action:Contact heating of plate specimen
Temperature Range:Ambient to 150°C
Electrical Feedthroughs:PT100 x 2
Rotary Feedthough:BMD-300 Magnetic Coupling
Motor:NX-210 a.c. Servo Motor


Automatically Controlled Parameters
Frequency
Plate specimen temperature
Test duration


Manually Controlled Parameters
Carico
Stroke
Chamber pressure (external service)


Measured Parameters
Friction
Plate specimen temperature
Chamber temperature
Chamber pressure
Number of cycles


Derived Parameters
Friction coefficient


Services
Electricity:220/240V, single phase 50/60 Hz, 7.5 kW
Process Gas System:Not included


ATex RatingThe machine, drive motor and associated instrumentation are ATex rated. The chiller unit, vacuum pump, power module and PC control and data acquisition system are not ATex rated. It follows that these items must be installed outside any ATex rated test cell, with suitable ATex rated connections between the operator work-station and the test cell.


Disclaimer: Il contenuto di cui sopra è per riferimento e comunicazione solo tra addetti ai lavori del settore e non garantisce la sua accuratezza o completezza. Secondo le leggi e i regolamenti pertinenti e i regolamenti di questo sito web, le unità o le persone fisiche che acquistano articoli correlati devono ottenere qualifiche e condizioni di qualificazione valide.


Messaggio online

Dettagli di contatto

Telefono aziendale

+86-21-6420 0566

Orario di lavoro

Da lunedì a venerdì

Telefono cellulare:

13816217984

Posta elettronica:

info@qinsun-lab.com

Codice QR