Compliance StandardsEN 702, EN 12477, EN 407, ISO 12127Scope of ApplicationSuitable for testing ther
Email: info@standard-groups.com
Norme di conformità
EN 702, EN 12477, EN 407, ISO 12127
Scope of Application
Suitable for testing thermal protection performance of firefighter suits, heat-resistant gloves, and related materials.
Dettagli del prodotto
The contact heat resistance tester evaluates materials' ability to withstand high-temperature contact heat by measuring the time required for specimen temperature to rise 10°C under specified pressure and heating conditions. This critical time determination provides quantitative assessment for thermal protection material development and performance evaluation.
Technical Specifications
1. High-temperature heating element (Φ25.2mm) with:
a. Sensitive thermocouple sensor
b. Temperature settable from room temperature to 500°C
2. Insulated heating element coating to prevent heat dissipation interference
3. 49N contact force provided by weighted pressure plate
4. Alumina-anodized temperature probe (Φ25mm, 5mm) with ±0.1°C accuracy
5. Motorized sample holder system:
a. 5mm/s precise motion control
b. Contact heating body at controlled speed
6. One-touch testing with LED display showing:
a. Initial specimen temperature
b. Real-time temperature
c. Critical 10°C rise time (±0.1s resolution)
7. Dimensions: 800×50×550mm (W×D×H)
8. Power requirement: 230V 50Hz AC
Disclaimer: Il contenuto di cui sopra è per riferimento e comunicazione solo tra addetti ai lavori del settore e non garantisce la sua accuratezza o completezza. Secondo le leggi e i regolamenti pertinenti e i regolamenti di questo sito web, le unità o le persone fisiche che acquistano articoli correlati devono ottenere qualifiche e condizioni di qualificazione valide.