MST Medical Compression Stocking Tester - Qinsun
Produttore di strumenti di prova professionali
Hotline nazionale di consultazione:+86 021-64208466

MST Medical Compression Stocking Tester

I. Product Overview The MST Medical Compression Stocking Tester is a specialized instrument designe

Email: info@standard-groups.com

Contenuto


I. Product Overview

IlMST Medical Compression Stocking Tester is a specialized instrument designed to evaluate the compression performance, elasticity, and durability of medical-grade compression stockings. It ensures compliance with healthcare standards by quantifying pressure distribution, hysteresis loss, and fabric resilience under repeated stress cycles.

  • Type: Automated textile testing system for medical compression wear
  • Key Metrics:
    • Compression Pressure Range: 15–50 mmHg (adjustable)
    • Pressure Accuracy: ±1 mmHg (ISO 13994 standard)
    • Elastic Recovery Rate (%): 95% min (AATCC 139)
  • Sample Size: 30×300mm (calf segment simulation)
  • Applications: Garment manufacturing, clinical research, quality assurance
II. Technical Specifications
Parametro Specifiche
Pressure Measurement Capacitive sensor array (0.1 mmHg resolution)
Test Modes Static pressure (1-minute hold) / Dynamic cyclic loading (10–100 cycles)
Sample Clamping Adjustable vacuum chuck (5–50 N grip force)
Uscita dati Pressure-time curve + CSV export
Alimentazione elettrica 220V/50Hz, 0.8kW
Dimensioni 600×400×800mm (L×W×H)
III. Key Features
  • Dual Test Modes:
    • Static Mode: Measures initial compression pressure
    • Dynamic Mode: Simulates walking motion (5–120 steps/min)
  • Advanced Analysis:
    • Pressure gradient mapping (ankle to knee)
    • Hysteresis loss calculation (ΔP vs cycles)
    • Real-time fabric strain visualization
  • Compliance:
    • ISO 13994 (Medical compression garments)
    • AATCC 139 (Textile elasticity)
    • YY/T 0561 (Chinese medical hosiery standard)
IV. Applications
  1. Quality Control: Batch testing of graduated compression stockings
  2. R&D: Developing pressure-mapping hosiery for lymphedema
  3. Clinical Research: Validating therapeutic compression levels
  4. Forensic Analysis: Evaluating garment failure in patient care
Standard Operation Workflow:
  1. Sample Preparation: Cut 30×300mm specimens from sock/tube
  2. Clamping: Secure sample in vacuum chuck with 20 N force
  3. Parameter Setup: Select test mode (static/dynamic) and cycle count
  4. Testing: Run pressure cycle (10–100x) with real-time monitoring
  5. Analysis: Generate pressure distribution heatmaps
Safety Precautions:
  • Avoid contact with sharp clamps during loading
  • Use medical-grade gloves when handling used samples
  • Calibrate sensors monthly per ISO 17025
* ISO 17025-calibrated pressure sensors * Medical-grade silicone clamps (latex-free) * Automated zero-drift compensation * Includes 5-year sensor calibration service * Compact design for clinic/lab use ​**Technical Highlights**​ - ±0.5 mmHg pressure measurement accuracy (AATCC 139 validated) - 100-cycle fatigue testing mode - Pressure gradient color mapping - WiFi data export to HIPAA-compliant platforms - CE/IECEx certified for medical environments

image.png

Disclaimer: Il contenuto di cui sopra è per riferimento e comunicazione solo tra addetti ai lavori del settore e non garantisce la sua accuratezza o completezza. Secondo le leggi e i regolamenti pertinenti e i regolamenti di questo sito web, le unità o le persone fisiche che acquistano articoli correlati devono ottenere qualifiche e condizioni di qualificazione valide.