Femoral Stem Fatigue Performance Testing Machine
StandardASTM F2003 (Standard Test Method for Fatigue Testing of Orthopedic Implants)ISO 14879-1 (Tot
Email: info@standard-groups.com
Contenuto
Standard
- ASTM F2003 (Standard Test Method for Fatigue Testing of Orthopedic Implants)
- ISO 14879-1 (Total Hip Joint Prostheses - Fatigue Testing of Femoral Stems)
- FDA 21 CFR Part 820 (Quality System Regulation for Medical Devices)
Vantaggi del prodotto
- Biomechanically Accurate Testing
- Multi-axis load application (axial, bending, torsion) replicates physiological gait cycles with ±1% force accuracy.
- High-Frequency Performance
- 50 Hz operation accelerates testing cycles, reducing time-to-market for new implant designs.
- Advanced Data Analytics
- AI-powered software predicts fatigue life (S-N curves) and identifies crack initiation points using real-time strain mapping.
- User-Centric Design
- 15.6-inch touchscreen interface with multilingual support (English, German, Chinese, Japanese) and one-touch test protocol selection.
- Regulatory Compliance
- Built-in audit trails, electronic signatures, and 21 CFR Part 11 compliance for seamless FDA/CE submissions.
Caratteristiche del prodotto
- Multi-Modal Testing:
- Axial Compression: 0–10 kN (±0.01 kN accuracy).
- Bending Moment: 0–50 Nm (±0.05 Nm accuracy).
- Torsional Load: ±180° rotation (0.01° resolution).
- Combined Loading: Programmable waveforms for simultaneous axial/bending/torsional stress.
- Controllo ambientale:
- Temperature-regulated bath (-20°C to +50°C) for simulating in-vivo conditions (e.g., cryogenic fatigue).
- Safety First:
- Overload protection, emergency stop, and laser-guided specimen alignment prevent sample damage and operator injury.
- Modular Expandability:
- Optional upgrades for high-temperature testing, corrosion simulation, and third-party software integration.
Parametri tecnici
Parametro | Specificazione |
---|
Axial Load Capacity | 0–10 kN (±0.01 kN accuracy) |
Bending Moment Capacity | 0–50 Nm (±0.05 Nm accuracy) |
Torsional Range | ±180° (0.01° resolution) |
Frequency Range | 0.1–50 Hz (adjustable) |
Controllo della temperatura | -20°C to +50°C (±0.5°C accuracy) |
Data Acquisition Rate | 100,000 Hz (strain/load channels) |
Alimentazione elettrica | 220V/110V AC, 50/60Hz, 2.5kW |
Dimensions (L×W×H) | 1.2×0.8×1.8 m |
Peso | 350 kg |
Operating Environment | 10–35°C, ≤70% RH (non-condensing) |
Accessories Included
- Specimen Clamps: Adjustable fixtures for femoral stems (Ø8–25mm).
- Calibration Kit: Load cell, torque sensor, and certification for annual validation.
- Safety Gear: Heat-resistant gloves, face shield, and emergency eyewash station.
- User Manual & Software: Digital guide (multilingual) + AI analytics platform for fatigue life prediction.
- Environmental Chamber: Temperature-controlled bath with antifreeze additive.
Ideal For:
- Orthopedic implant manufacturers (hip/knee prostheses)
- Medical device testing laboratories
- Regulatory certification bodies (FDA, CE, TÜV)
- Biomechanical research institutions
Disclaimer: Il contenuto di cui sopra è per riferimento e comunicazione solo tra addetti ai lavori del settore e non garantisce la sua accuratezza o completezza. Secondo le leggi e i regolamenti pertinenti e i regolamenti di questo sito web, le unità o le persone fisiche che acquistano articoli correlati devono ottenere qualifiche e condizioni di qualificazione valide.