Detailed Product DescriptionSKYLINE:Salt Spray TesterVolume:270LMaterial:PVC Sheet, Thickness 5

WhatsApp : +86 13816217984

Email : info@qinsun-lab.com

Contenuto

Detailed Product Description

SKYLINE:Salt Spray TesterVolume:270L
Material:PVC Sheet, Thickness 5 MmStandard:CNS3627, 3885, 4159, 7669, 8886, JIS Do201, H8502, H8610, K5400, Z2371, ISO3768, 3769, 3770, 9227, ASTM B117, B268
Inner Dimension:900 × 600 × 500mm (W * D * H) MmMaterial For Saturated Air Barrel:SUS #304 Stainless Steel Barrel High Pressure Barrel


Parametri tecnici

  (mm)Inner Box Size600x400x450900x600x5001200x1000x5001600x1000x500

(mm)

Outer Box Size

1070x600x11801310x1280x8801900x1400x13002300x1400x1300

Capacity

108L270L600L800L

Salt water tank capacity

15L25L40L40L

Spray Pressure

1.00±0.1kgf/cm²

Spray Volume

1.0-2.0ml/80cm²/h

1.0-2.0ml/80cm²/h(Collect at least 16 hours and take the average)

Relative Humidity

>85%RT

Materials
1. Laboratory imported PVC polyethylene plate, thickness 5mm, durable temperature at 85 ℃.
2. Laboratory seal cover imported European acrylic board, thickness 5mm.
3. Reagent bottle with a hidden surface with a water table, easy to clean, easy to rupture.
4. Pressure air bucket with SUS # 304 stainless steel high pressure barrel insulation effect is the best
5. Laboratory basket drawing plane indexing frame, can be arbitrarily adjusted angle, surrounded by fog and fog aspects are exactly the same, the number of test pieces placed.

According to CNS.JIS.ASTM specifications, can be set to constant temperature control:

 Salt spray test NSS (neutral), ACSS (acid) AASS (acetate spray test)
 Laboratory:Pressure air bucket: 35 ℃ ± 1 ℃ 47 ℃ ± 1 ℃
 Corrosion resistance test CASS (copper acetate)
 Laboratory:Pressure air bucket: 50 ℃ ± 1 ℃ 63 ° C ± 1 ° C

The air supply system:

air pressure 1kg / cm² two-stage adjustment
The first adjustment for the 2kg / cm² imported air filter with drainage function;
The second adjustment is 1kg / cm² pressure.

Spray way
1. The use of the principle of Bernoutt to absorb salt water and then atomization, uniform degree of atomization, no blocking the phenomenon of crystallization, to ensure continuous testing of the standard.
2. Nozzle: Made of special glass nozzle, can adjust the size of the spray.
3. Spray volume adjustment 1-2mI (mI / 80cm² / h) (16 hours average)
4. Spray mode: continuous type
5. The use of direct heating, heating speed to reduce the standby time, when the temperature reaches ON.OFF switch, the temperature is accurate, low power consumption.
(Heating tube made of high corrosion resistance heating system: titanium tube).

The control system:
1. Laboratory temperature controller 0-99.9 ℃, liquid crystal double digital no display with P.I.D automatic calculation, control error ± 0.3 ℃ (YANGMING) Taiwan 1
2. Pressure air barrel temperature control 0-99.9 ℃, liquid crystal double digital no display with P.I.D automatic calculation, control error ± 0.3 ℃ (YANGMING) Taiwan 1
3. Laboratory heating tank liquid expansion safety temperature control 1-120 ℃ (Italy) 1 only
4. Pressure air bucket liquid expansion safety temperature control 1-120 ℃ (Italy) 1 only
5. Digital display time control 0.1S-9999hr (Taiwan Anliang) 1 only
6. Accumulator 0-99999 hr (Italy) 1 only
7. Relay (Japan OMRON OMRON) 5 only
8. Spray solenoid valve (imported KSD) 1 only
9. Defog solenoid valve (imported KSD) 1 only
10. Laboratory automatic water solenoid valve 1 only
11. Pressure bucket automatic water solenoid valve 1 only
12. Board light type chargeback switch, can be a continuous charge of 20000 times 1
13. Water system: the use of automatic water supplement system, a
14. salt spray sealed sink: a way to automatically add water

Security devices
(A) low water level, automatically cut off the power supply device.
(B) overheating, automatically cut off the heater power supply device.
(C) with safety warning light device.
(D) at the end of the warning light automatic warning.

Disclaimer: Il contenuto di cui sopra è per riferimento e comunicazione solo tra addetti ai lavori del settore e non garantisce la sua accuratezza o completezza. Secondo le leggi e i regolamenti pertinenti e i regolamenti di questo sito web, le unità o le persone fisiche che acquistano articoli correlati devono ottenere qualifiche e condizioni di qualificazione valide.


Messaggio online

Dettagli di contatto

Telefono aziendale

+86-21-6420 0566

Orario di lavoro

Da lunedì a venerdì

Telefono cellulare:

13816217984

Posta elettronica:

info@qinsun-lab.com

Codice QR