Standard

  • ANSI/UL 94: Standard for Safety of Flammability of Plastic Materials for Parts in Devices and Appliances
  • GJB 360B-2009: Test Methods for Electronic and Electrical Components (Military Standard)
  • GB/T 5169.16-2008: Fire Hazard Testing – Part 16: Correlation of Thermal and Mechanical Surface Flammability
  • IEC 60950-1: Safety of Information Technology Equipment
  • ISO 13943: Fire Safety – Vocabulary (Referenced for Flammability Testing)

Vantaggi del prodotto

  1. Dual-Mode Testing: Supports horizontal/vertical combustion analysis (0°, 20°, 45° angles).
  2. Full Automation: PLC + touchscreen control for ignition, timing, data logging, and burner retraction.
  3. Precision Control: Adjustable flame height (20–130 mm), temperature (100–1000°C), and gas flow (0–1000 ml/min).
  4. Safety Compliance: Auto-gas shutoff, silent exhaust system, and optional gas alarm reduce operational risks.
  5. Data-Driven: Auto-calculates linear combustion rate (V) and stores results for regulatory compliance.
  6. Flexible Sample Handling: Adjustable clamps accommodate diverse material sizes and thicknesses.

Caratteristiche del prodotto

  • Touchscreen Interface: Programmable controller with one-touch operation for ignition, timing, and data storage.
  • Automatic Burner System: Retracts post-test; optional gas shutoff prevents residual flames.
  • Flame Calibration: Optional thermocouple (K-type) and copper block ensure precise temperature control (100–700°C in ≤44s).
  • Multi-Angle Testing: Adjustable sample holder for horizontal (0°), 20°, or 45° vertical combustion.
  • High-Capacity Chamber: >0.5 m³ stainless steel box (non-calibrated options: 0.75 m³/1 m³) with black background (<20 Lux).
  • Exhaust System: Silent anti-backflow device removes combustion smoke post-test.

Parametri tecnici

ParametroSpecificazione
Test ModesHorizontal/Vertical (0°, 20°, 45°)
Sistema di controlloPLC + 7-inch Touchscreen
Flame Height20–130 mm (Adjustable)
Flame Temperature100–1000°C (Adjustable)
Gas Flow0–1000 ml/min (Adjustable)
Burner SpecsInner Diameter: 9.5 ±0.3 mm; Length: 100 ±10 mm
Timer Range/Accuracy0–999.9 s (±0.2 s for 10s/30s)
Combustion Rate (V)Auto-Calculated by PLC (Displayed/Saved)
Sample AdjustmentUp/Down, Left/Right, Front/Back (Large Stroke)
Chamber Volume>0.5 m³ (900 × 590 × 1050 mm)
Alimentazione elettricaAC 220V ±10%, 50Hz, 150W
Dimensions (W×D×H)1160 × 600 × 1310 mm (Incl. Feet)
Net Weight100 kg
Gas SourceLiquefied Petroleum Gas (Methane for Arbitration)
 


 
 

Disclaimer: Il contenuto di cui sopra è per riferimento e comunicazione solo tra addetti ai lavori del settore e non garantisce la sua accuratezza o completezza. Secondo le leggi e i regolamenti pertinenti e i regolamenti di questo sito web, le unità o le persone fisiche che acquistano articoli correlati devono ottenere qualifiche e condizioni di qualificazione valide.


Messaggio online

Dettagli di contatto

Telefono aziendale

+86-21-6420 0566

Orario di lavoro

Da lunedì a venerdì

Telefono cellulare:

13816217984

Posta elettronica:

info@qinsun-lab.com

Codice QR