Orario: Popolarità:0volte
Parametro | Specificazione |
---|---|
Chamber Size | Customizable for 18650, 21700, and prismatic cells |
Temperature Range | Ambient to 700°C ±2°C |
Flame Height Control | Adjustable up to 75mm ±2mm |
Safety Features | Emergency stop, explosion-proof chamber, double-layer tempered glass |
Materiale | High-temperature SUS304 stainless steel interior |
Data Accuracy | ±0.5% temperature, ±2mm positioning |
The machine uses a propane-fueled burner to generate controlled flames, which are directed at battery samples. A PLC system adjusts flame height and duration, while sensors monitor real-time temperature, voltage, and gas emissions. The test chamber is equipped with exhaust vents to manage fumes and maintain operator safety.
This machine empowers manufacturers to mitigate thermal-related risks, ensuring batteries meet stringent safety standards and reducing field failures.
Telefono aziendale
+86-21-6420 0566
Orario di lavoro
Da lunedì a venerdì
Telefono cellulare:
13816217984
Posta elettronica:
info@qinsun-lab.com