Adiabatic Rate Calorimeter - Qinsun
Produttore di strumenti di prova professionali
Hotline nazionale di consultazione:+86 021-64208466
Prodotti

Adiabatic Rate Calorimeter

Adiabatic Rate Calorimeter (ARC) for evaluating thermal hazards.

WhatsApp: +86 13816217984

Email: info@qinsun-lab.com

Contenuto

Descrizione del prodotto

Battery Isothermal Calorimeter is a professional instrument developed based on the principle of power compensation isothermal calorimetry for testing the thermal characteristics of various types of lithium batteries, capable of realizing the measurement of the thermal characteristics of lithium batteries' charging and discharging as well as the thermal and physical parameters, providing accurate, stable and reliable basic thermal data for the thermal simulation of batteries, the optimization of the design of the thermal management system, as well as the assessment of the thermal safety performance of batteries.


Caratteristiche del prodotto

1. In an isothermal environment, it is compatible with the power compensation method and the heat - flow method to measure the heat generated during battery charging and discharging. This not only ensures the accuracy of thermal characteristic measurement for relatively large - sized batteries but also improves the sensitivity of heat measurement for relatively small - sized batteries.

2. It has an instrument calibration mode, which can calibrate the measurement accuracy of charging and discharging thermal behavior parameters under different conditions.

3. It is equipped with a heat capacity measurement mode. By using the comparative method to measure heat capacity, it reduces the operational requirements for heat capacity testing and can accurately measure the heat capacity of batteries at different temperatures.

4. The integrated battery charging and discharging module enables the switching of charging and discharging modes, the setting of constant - current/constant - voltage charging modes, the setting of charging/discharging currents, and the real - time calculation of battery power.

5. Network communication is adopted to achieve remote operation of the instrument and remote data transmission, ensuring the safety of testers.

6. It can simultaneously record voltage, current, and temperature data during the battery charging and discharging process.

7. An optional nitrogen purging module can be selected to ensure the accuracy of low - temperature measurement and effectively suppress the problem of low - temperature condensation.


Technical Specifications Parameters

Calorimeter Body

(5~40)°C, <85%RH

Operating Environment

(-40~100)ºC

Oil Bath Temperature Control Range

Isothermal Power Compensation Mode, Isothermal Heat Flow Mode, Specific Heat Capacitance Mode

Experimental Modes

±0.005°C

Temperature Stability

0.001°C

Temperature Resolution

L345mm×W230mm×H100mm

Maximum Cell Size

200W

Maximum Compensated Power

10mW (power compensation mode); 0.2mW (heat flow mode)

Calorimetric Sensitivity

±1% (power compensation mode); ±2% (heat flow mode)

Absorption and Expiration Enthalpy Measurement Accuracy

10mW (Power Compensation Mode); 0.2mW (Heat Flow Mode)

Baseline Noise

Standard with 2 channels

Heating Channels

Standard with 8 channels

Temperature Measurement Channels

RJ45

Instrument Interfaces

(5~25)L/min

Adjustable Gas Flow Rate

AC220V/50Hz

Power Supplied Power Supply

600W

Maximum Power

(-55~200 )°C

Oil Bath

±0.01°C

Setting Temperature Range

0.01°C

Temperature Stability

3kW

Display Resolution

1.5kW@20°C, 1.5kW@0°C, 1kW@-20°C, 0.3kW @-40°C

Heating Power

12×11/16cm

Refrigeration Power

5L

Bath Openings/Size

Serial port

Charging

(5~40)°C, <85%RH

Calorimeter Body

(-40~100)ºC 


企业微信截图_1741749064820.png

Disclaimer: Il contenuto di cui sopra è per riferimento e comunicazione solo tra addetti ai lavori del settore e non garantisce la sua accuratezza o completezza. Secondo le leggi e i regolamenti pertinenti e i regolamenti di questo sito web, le unità o le persone fisiche che acquistano articoli correlati devono ottenere qualifiche e condizioni di qualificazione valide.


Messaggio online

Dettagli di contatto

Telefono aziendale

+86-21-6420 0566

Orario di lavoro

Da lunedì a venerdì

Telefono cellulare:

13816217984

Posta elettronica:

info@qinsun-lab.com

Codice QR