Detailed Product DescriptionHydrogen Flame Ionization Detector (FID:Cylindrical Collector Struc
WhatsApp : +86 13816217984
Email : info@qinsun-lab.com
Hydrogen Flame Ionization Detector (FID: | Cylindrical Collector Structure Design, Metal Nozzle | Detection limit: | ≤2×10-12g/s (n-hexadecane/isooctane) |
---|---|---|---|
Baseline noise: | ≤10μV | Baseline drift: | ≤100μV/30min |
Linearity: | ≧105 | Adjustable fully automatic ignition, stabilization time: | 30 Minutes |
Thermal Conductivity Detector (TCD): | Semi-diffused Structure, Constant Current Control Mode For Power Supply | Sensitivity: | ≥5000mV·ml/mg |
Temperature range: | 5°C~420°C Above Room Temperature Accuracy ±0.1°C | Power supply: | 220V±22V, 50Hz |
Power: | ≥2kW | Weight: | 55KG |
Dimensions: | 60cm×50cm×50cm | ||
Highlight: | Semi Diffused Structure Gas ChromatographInsulating Oil Gas Chromatograph |
It is designed and manufactured according to the methods stipulated in GB/T 17623 and DL/T 703 standards, and is suitable for analyzing oil-filled electrical equipment (including transformers, reactors, current transformers, voltage transformers, charging bushings, etc.) Analysis of hydrogen, carbon monoxide, methane, carbon dioxide, ethylene, ethane, acetylene and other gas content in oil.
Realize computer real-time control and data processing:
High-precision, stable and reliable temperature control system:
The heater will stop heating and report the fault location on the display;
Simple and clear man-machine dialogue interface, easy to operate, easy to learn and use
Double stable high-precision air path control system.
The column chamber adopts the method of tracking temperature rise.
The instrument detects low-level hydrocarbons and high-level CO and CO2. which can be detected separately to avoid mutual interference.
Hydrogen Flame Ionization Detector (FID) | Cylindrical collector structure design, metal nozzle |
Detection limit | ≤2×10-12g/s (n-hexadecane/isooctane) |
Baseline noise | ≤2×10-13A |
Baseline drift | ≤2×10-12A/30min |
Linearity | ≥106 |
Adjustable fully automatic ignition, stabilization time | 30 minutes |
Thermal Conductivity Detector (TCD) | Semi-diffused structure, constant current control mode for power supply |
Sensitivity | ≥5000mV·ml/mg |
Baseline noise | ≤10μV |
Baseline drift | ≤100μV/30min |
Linearity | ≧105 |
Intervallo di temperatura | 5°C~420°C above room temperature Accuracy ±0.1°C |
Alimentazione elettrica | 220V±22V, 50Hz |
Potenza | ≥2kW |
Peso | 55KG |
Dimensioni | 60cm×50cm×50cm |
Disclaimer: Il contenuto di cui sopra è per riferimento e comunicazione solo tra addetti ai lavori del settore e non garantisce la sua accuratezza o completezza. Secondo le leggi e i regolamenti pertinenti e i regolamenti di questo sito web, le unità o le persone fisiche che acquistano articoli correlati devono ottenere qualifiche e condizioni di qualificazione valide.